Test Code CRGSP Cryoglobulin and Cryofibrinogen Panel, Serum and Plasma
Additional Codes
LAB713
Reporting Name
Cryo Panel, S and PUseful For
Evaluating patients with vasculitis, glomerulonephritis, and lymphoproliferative diseases
Evaluating patients with macroglobulinemia or myeloma in whom symptoms occur with cold exposure
This test is not useful for general screening of a population without a clinical suspicion of cryoglobulinemia.
Profile Information
| Test ID | Reporting Name | Available Separately | Always Performed |
|---|---|---|---|
| CRY_S | Cryoglobulin, S | Yes | Yes |
| CRY_P | Cryofibrinogen, P | No | Yes |
Reflex Tests
| Test ID | Reporting Name | Available Separately | Always Performed |
|---|---|---|---|
| IMFXC | Immunofixation Cryoglobulin | No | No |
Testing Algorithm
If cryoglobulin has a positive result after 1 or 7 days, then immunofixation will be performed at an additional charge. Immunofixation will only be performed once when positive cryoglobulin results are 0.1 mL of precipitate or greater.
Performing Laboratory
Mayo Clinic Laboratories in Rochester
Specimen Type
Plasma EDTASerum Red
Specimen Required
Both plasma and serum are required.
Patient Preparation: Fasting: 12 hours, preferred but not required
Specimen Type: Plasma
Collection Container/Tube: Lavender top (EDTA)
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL Plasma
Collection Instructions:
1. Tube must remain at 37° C.
2. Centrifuge at 37° C. Do not use a refrigerated centrifuge. If absolutely necessary, ambient temperature is acceptable. It is very important that the specimen remains at 37° C until after separation of plasma from red blood cells.
3. Place plasma into an appropriately labeled plastic vial.
Specimen Type: Serum
Collection Container/Tube: Red top (serum gel/SST are not acceptable)
Submission Container/Tube: Plastic vial
Specimen Volume: 5 mL Serum
Collection Instructions:
1. Tube must remain at 37° C.
2. Allow blood to clot at 37° C.
3. Centrifuge at 37° C. Do not use a refrigerated centrifuge. If absolutely necessary, ambient temperature is acceptable. It is very important that the specimen remains at 37° C until after separation of serum from red blood cells.
4. Place serum into an appropriately labeled plastic vial.
Additional Information: Analysis cannot be performed with less than 3 mL of serum. Smaller volumes are insufficient to detect clinically important trace (mixed) cryoglobulins. Less than 3 mL will require collection and submission of a new specimen.
Specimen Minimum Volume
Plasma: 0.5 mL; Serum: 3 mL
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Plasma EDTA | Refrigerated (preferred) | |
| Frozen | ||
| Serum Red | Refrigerated (preferred) | |
| Frozen | ||
Reference Values
CRYOGLOBULIN
Negative
Positive results are reported as a percentage or trace amount.
CRYOFIBRINOGEN
Negative
Day(s) Performed
Monday through Friday
CPT Code Information
82585
82595
86334-Immunofixation (if appropriate)
LOINC Code Information
| Test ID | Test Order Name | Order LOINC Value |
|---|---|---|
| CRGSP | Cryo Panel, S and P | 74352-6 |
| Result ID | Test Result Name | Result LOINC Value |
|---|---|---|
| 2685 | Cryofibrinogen, P | 11043-7 |
| 2684 | Cryoglobulin, S | 12201-0 |
Report Available
2 to 10 daysMethod Name
CRY_S, CRY_P: Quantitation and Qualitative Typing Precipitation
IMFXC: Immunofixation
Forms
If not ordering electronically, complete, print, and send a Benign Hematology Test Request Form (T755) with the specimen.